2009-2013 by Fairbanks Scales, Inc. 51214 All rights reserved Rev. 8 01/13 FB2250 Series Instrument PC2250 Utility Software
Section 1: General Information 6/12 10 51214 Rev. 7 Accessories Optional accessories include the following. FIELDBUS DEVICES • DeviceNet™
Section 1: General Information 6/12 11 51214 Rev. 7 Powering up the FB2250 Press the ON / OFF Key for 1 to 2 seconds. The Instrument will d
6/12 12 51214 Rev. 7 Section 2: Front Panel Programming Front Panel Programming Parameters
Section 2: Front Panel programming 6/12 13 51214 Rev. 7 Press the Print key for 3 seconds. Programming Time Format: Press the ZERO key. Pre
Section 2: Front Panel programming 6/12 14 51214 Rev. 7 CLr.ACC: Clearing the Accumulator: Conditional upon programming the operating mode
6/12 15 51214 Rev. 7 Section 3: Operation Front Panel Key Functions ON/OFF Turns the Instrument on or off. UNITS Switches between pre-
Section 3: Operation 6/12 16 51214 Rev. 7 Instrument Weighing Functions The industry uses three terms to describe the apportionment of an
Section 3: Operation 6/12 17 51214 Rev. 7 Weight Accumulation 1. Place a weight on the Scale Platform 2. After the weight has settled. Pres
Section 3: Operation 6/12 18 51214 Rev. 7 Parts Counting and Accumulation 1. Place the Container on the Scale Platform. 2. Press the TARE
Section 3: Operation 6/12 19 51214 Rev. 7 Peak Weight Either the Maximum Unstable or Maximum Stable Peak Weights, are stored along with the
6/12 2 51214 Rev. 7 Amendment Record FB2250 Series Instrument PC2250 Utility Software Document 51214 Manufactured by Fairbanks Scales Inc. 821
6/12 20 51214 Rev. 7 Section 4: Accessories 4-20 mA Analog Output 16 bit Resolution and Monotonicity 0.01% Non-Linearity Front Panel Programma
Section 4: Accessories 6/12 21 51214 Rev. 7 4-20 mA Instrument Setup Press the Units key for 3 seconds NOTE: Conditional upon service pro
Section 4: Accessories 6/12 22 51214 Rev. 7 Fieldbus Fairbanks Scales offers three different fieldbus devices modules; Profibus®, DeviceNe
Section 4: Accessories 6/12 23 51214 Rev. 7 Fieldbus Connections: Profibus® Pin Signal Description 3 B Line Positiv
Section 4: Accessories 6/12 24 51214 Rev. 7 Profibus® Diagnostic LED’S: 1: Operation Mode LED 2: Module Status LED Operation Mo
Section 4: Accessories 6/12 25 51214 Rev. 7 DeviceNet™ Diagnostic LED’S: 1: Network Status LED 2: Module Status LED 3: DeviceNet™ conn
Section 4: Accessories 6/12 26 51214 Rev. 7 Ethernet / IP Diagnostic LED’S: 1: Network Status LED 2: Module Status LED 3: Link/A
6/12 27 51214 Rev. 7 Section 5: Serial Communication Wiring JP3 Jumper Configuration: JP3 RS232 RS485 RS422* Port 1-2 out
6/12 28 51214 Rev. 7 Section 6: Printer Installation 3550 Tape Printer The FB2250 should be programmed for RS 232, 9600 baud, 8 data bits, an
Section 6: Printers 6/12 29 51214 Rev. 7 Okidata 186 T Form Printer The FB2250 should be programmed for RS 232, 9600 baud, 8 data bits,
6/12 3 51214 Rev. 7 Disclaimer Every effort has been made to provide complete and accurate information in this manual. However, although this
Section 6: Printers 6/12 30 51214 Rev. 7 (GROUP) (ITEM) (SET) (press LINE FEED (press FORM FEED (press TOF SET to chan
Section 6: Printers 6/12 31 51214 Rev. 7 Serial PCB Assy Switch Settings: (SW1) (** indicates typical Fairbanks setting) Parity Type
Section 6: Printers 6/12 32 51214 Rev. 7 (SW2) (** indicates typical Fairbanks setting) Transmission Speed Switches 1, 2, 3 (SW2)
Section 6: Printers 6/12 33 51214 Rev. 7 Okidata 420 Form Printer The FB2250 should be programmed for RS 232, 9600 baud, 8 data bits, and
Section 6: Printers 6/12 34 51214 Rev. 7 (GROUP) (ITEM) (SET) (press LINE FEED (press FORM FEED (press TOF SET to chan
Section 6: Printers 6/12 35 51214 Rev. 7 Set-Up Graphics Uni-directional Set-Up Receive Buffer Size 64K Set-Up
Section 6: Printers 6/12 36 51214 Rev. 7 TM-U295 Ticket Printer The FB2250 should be programmed for RS232, 9600 baud, 8 data bits, and 1
Section 6: Printers 6/12 37 51214 Rev. 7 TM-U590 Ticket Printer The FB2250 should be programmed for RS232, 9600 baud, 8 data bits, and 1
Section 6: Printers 6/12 38 51214 Rev. 7 Remote Display Utilizing the 20 mA serial current loop output will enable transmission to 1000
6/12 39 51214 Rev. 7 Section 7: PC2250 Utility Software Introduction The PC2250 utility software program can be used to set up and configure
6/12 4 51214 Rev. 7 Table of Contents SECTION 1: GENERAL INFORMATION ... 6 Mode
Section 7: PC2250 Utility Software 6/12 40 51214 Rev. 7 Files The default folder for all saved/uploaded parameter files is PC2250\SAVED
Section 7: PC2250 Utility Software 6/12 41 51214 Rev. 7 When complete, click the “OK” button. DOWNLOAD: Downloads the current PC
Section 7: PC2250 Utility Software 6/12 42 51214 Rev. 7 Configuration Programming features is accomplished by using the mouse and: Clic
Section 7: PC2250 Utility Software 6/12 43 51214 Rev. 7 Calibration Settings include Scale capacity, Primary Units, Auto Zero Tracking,
Section 7: PC2250 Utility Software 6/12 44 51214 Rev. 7 Fieldbus / 4-20 mA The Anybus or DeviceNet Module is set up using the PC2250 Pro
Section 7: PC2250 Utility Software 6/12 45 51214 Rev. 7 Endian The endianess of module is determined by the network type but can be change
Section 7: PC2250 Utility Software 6/12 46 51214 Rev. 7 INPUT Single byte Commands can be sent from the network. Although the input is rea
Section 7: PC2250 Utility Software 6/12 47 51214 Rev. 7 Custom Output: Settings Checksum: This setting determines whether a checksum c
Section 7: PC2250 Utility Software 6/12 48 51214 Rev. 7 Custom Output: Load A variety of pre-packaged output strings is
Section 7: PC2250 Utility Software 6/12 49 51214 Rev. 7 Custom Output: Build The data output string can be customized to suit the applica
Section 1: General Information 6/12 5 51214 Rev. 7 SECTION 6: PRINTER INSTALLATION ...
Section 7: PC2250 Utility Software 6/12 50 51214 Rev. 7 Custom Output: Tokens A wide variety of different characters ca
Section 7: PC2250 Utility Software 6/12 51 51214 Rev. 7 This will produce an additional data entry box as shown. Selecting data items
Section 7: PC2250 Utility Software 6/12 52 51214 Rev. 7 Custom Output: Weights A variety of different settings is also
Section 7: PC2250 Utility Software 6/12 53 51214 Rev. 7 Format tickets Formatting tickets is easily performed with this
Section 7: PC2250 Utility Software 6/12 54 51214 Rev. 7 Printed Examples: Accumulation. Piece Count & Total: Printing time, d
6/12 55 51214 Rev. 7 Appendix I: Data Output Formats General Notes: <CR> = means carriage return character. <LF> = line feed chara
Appendix I: Data Output Formats 6/12 56 51214 Rev. 7 Status Word B Bit # Description 0 Gross = 0 Net = 1 1
Appendix I: Data Output Formats 6/12 57 51214 Rev. 7 Condec Continuous Output <STX><P><WWWWWWW><U><G><M&g
Appendix I: Data Output Formats 6/12 58 51214 Rev. 7 Gross Weight – Motion – decimal points included <SP> <W> <W> <W
Appendix I: Data Output Formats 6/12 59 51214 Rev. 7 UPS Serial Data Output Format for UPS Worldship Software. The instrument will tran
6/12 6 51214 Rev. 7 Section 1: General Information Model Descriptions The FB2250 is a general purpose weighing instrument that can be used wi
Appendix I: Data Output Formats 6/12 60 51214 Rev. 7 P Ship Serial Data Output Format for P Ship, used to interface to FedEx Shipping Prog
Appendix I: Data Output Formats 6/12 61 51214 Rev. 7 5. Interpretation of scale status digits The high order nibble of each status byte ha
6/12 62 51214 Rev. 7 Appendix II: ASCII Chart Char Dec Hex NUL 0 0 SOH 1 1 STX 2 2 ETX 3 3 EOT 4 4 ENQ 5 5 ACK 6 6 BEL 7
Appendix III: FB2250 Remote Display Wiring RS232 INTERFACE WIRING FB2250 (ABS) REMOTE DISPLAY FB2250 (ABS) REMOTE DISPLAY FB2250 (SS) REMOTE
6/12 64 51214 Rev. 7 Appendix IV: Remote Display Active Keys INSTRUMENT FB2250 ACTIVE FRONT PANEL KEYS FB2200 No Active Keys FB2250 Units, Ze
6/12 65 51214 Rev. 7 Appendix V: Remote PC Commands Transmitting certain ASCII characters to the FB2250 will duplicate a key-press from a remo
FB2250 Series Instrument Document 51214 Manufactured by Fairbanks Scales, Inc. 821 Locust Street Kansas City, MO 64106 w
51233 © 2009-2010 by Fairbanks Scales, Inc. Revision 4 11/10 All rights reserved 3500 Series Yellow Jacket Mild Steel Floor Scale
Section 1: General Information 6/12 7 51214 Rev. 7 Main Product Features, Continued • The PC2250 software utility program can also upload
11/10 3 51233 Rev. 4 Amendment Record 3500 SERIES MILD STEEL FLOOR SCALE Document 51233 Manufactured by Fairbanks Scales, Inc. 82
11/10 4 51233 Rev. 4 Disclaimer Every effort has been made to provide complete and accurate information in this m
11/10 5 51233 Rev. 4 Table of Contents SECTION 1: GENERAL INFORMATION ...
11/10 6 51233 Rev. 4 Section 1: General Information INTRODUCTION The 3500 Series Floor Scale uses a summing junction box for inter
11/10 7 51233 Rev. 4 Section 2: Company Service Information GENERAL SERVICE POLICY Prior to installation, always verify that the e
Section 2: Company Service Information 11/10 8 51233 Rev. 4 OVERVIEW Physical Installation Notes Check all devices for proper o
Section 2: Company Service Information 11/10 9 51233 Rev. 4 Pre-Installation Checklist The following points should be checked and
Section 2: Company Service Information 11/10 10 51233 Rev. 4 Equipment Checkout Position the equipment with these points in mind:
11/10 11 51233 Rev. 4 Section 3: Scale Installation Installing the Scale 2. Select a location that is flat, solid, level, and one t
Section 1: General Information 6/12 8 51214 Rev. 7 Specifications, Continued Settings • Zero Range 2 % or 100% • Auto Zero Tracking OFF,
Section 3: Scale Installation 11/10 12 51233 Rev. 4 INSTALLATION, CONTINUED 8. Wire the scale cable to the proper type instrument
Section 3: Scale Installation 11/10 13 51233 Rev. 4 Calibration Steps Adjust the analog interface instrument to the platform.
Section 3: Scale Installation 11/10 14 51233 Rev. 4 If corners do require adjustment, complete the following steps: 1. Remove the
11/10 15 51233 Rev. 4 Section 4: Installing Accessories Installing Bolt-Down Plates Bolt down plates are used to keep the scale from
Section 4: Installing Accessories 11/10 16 51233 Rev. 4 Installing Ramps Each mild steel ramp accessory comes with two integral bol
11/10 17 51233 Rev. 4 Section 5: Parts Replacement Load Cell Replacement Steps 1. Cycle-down the power to the instrument, and the
Section 5: Parts Replacement 11/10 18 51233 Rev. 4 Load Cell Replacement Steps, Continued IMPORTANT NOTE: See Appendix I for spec
Section 5: Parts Replacement 11/10 19 51233 Rev. 4 Junction Box Replacement Steps 1. Remove power to the instrument. 2. Open the
11/10 20 51233 Rev. 4 Section 6: Parts Parts List ITEM PART NO. DESCRIPTION SCALE CAPACITIES1 See Appendix II Platform weldment Se
Section 6: Parts 11/10 21 51233 Rev. 4 Parts DiagramTHE MATERIAL AND INFORMATIONCONTAINED HEREIN IS CONFIDEN-TIAL AND IS THE PROPE
Section 1: General Information 6/12 9 51214 Rev. 7 Specifications, Continued Out of Range Warnings • HiCAP Scale input is over capacity •
11/10 22 51233 Rev. 4 Appendix I: Load Cells ITEM PART NO. DESCRIPTION SCALE CAPACITY 2 30238 1K lb Capacity Load Cell 350 O
11/10 23 51233 Rev. 4 Appendix II: Specifications PRODUCT NO. SIZE CAPACITY PLATFORM WELDMENT DECK 30325 4’ x 4’ 2,500 lbs 301
11/10 24 51233 Rev. 4 Appendix III: Accessories Ramps and Bumper Guards SIZE CAPACITY RAMP BUMPER GUARD 4’ x 30” 2,500 lbs 3025
3500 Series Floor Scale INSTALLATION MANUAL DOCUMENT 51233 Manufactured by Fairbanks Scales, Inc. 821 Locust St. Kansas City, MO 64106 www.fa
Comments to this Manuals